  for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g65 safety i nterlock switches D4SL D4SL compact 6-contact g uard l ock safety-door switch ? two types are available: a connector type that reduces wiring time and a detachable terminal block type. ? robust and durable metal head. ? key holding force of 1,300 n. ? the wider key slot is less susceptible to movement from doors, and can handle doors with a small radius. ? by rotating the mounting part, it is possible, both to change the key insertion point and to enable mounting on various devices. ? easy view led indicators can be checked from any direction. ? by utilizing the 6-contact type, both the door open/closed status and the solenoid on/off status can be monitored independently. ? a cost-effective 5-contact model is also available. standards and ec directives c onforms to the following ec directives: ? machinery directive ? low voltage directive ? emc directive ? en 1088 ? en 60204-1 ? gs-et-19 c ertifed standards c ertifcation body standard file no. tv sd en 60947-5-1 (certifed direct opening) consult your representative for details. ul *1 ul 508, csa c22.2 no.14 cqc (ccc) gb14048.5 kosha *2 en60947-5-1 *1. certifcation for csa c22.2 no. 14 is certifed by the ul mark. c ertifed standard ratings tv (en 60947-5-1) i tem utilization category a c-15 dc-13 rated operating current (ie) 1.5 a 0.22 a rated operating voltage (ue) 120 v 125 v note: use a 4 a fuse that conforms to iec 60127 as a short-circuit protection device. this fuse is not included with the switch. specifcations ul/csa (ul 508, csa c22.2 n o. 14) c150 rated voltage c arry current current (a) volt-amperes (va) make break make break 120 vac 2.5 a 15 1.5 1,800 180 r150 rated voltage c arry current current (a) volt-amperes (va) make break make break 125 vdc 1.0 a 0.22 0.22 28 28 solenoid coil characteristics item t ype 24 vd c rated operating voltage (100% ed) 24 vdc +10% -15% current consumption* power on: approx. 34 w at 1.4 a constant: approx. 2.6 w (average) at 0.4 a (max.) insulation class class e (120c max.) *a starting current is applied to the solenoid for a maximum of one second. after this, the internal circuit switches to constant current. indicator characteristics item t ype led rated voltage 24 vdc current consumption approx. 10 ma color (led) orange connector type terminal block type new! rev. 9.11 www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g66 characteristics degree of protection *1 ip67 (en60947-5-1) durability *2 mechanical 1,000,000 operations min. electrical 150,000 operations min. (1 a resistive load at 125 vac) *3 operating speed 0.05 to 1 m/s operating frequency 5 operations/minute max. direct opening force *4 60 n min. (en60947-5-1) direct opening travel *4 15 mm min. (en60947-5-1) holding force *5 1,300 n min. contact resistance 200 m max. minimum applicable load *6 1 ma resistive load at 5 vdc (n-level reference value) rated insulation voltage (ui) 150 v (en60947-5-1) rated frequency 50/60 hz protection against electric shock class ii (double insulation) pollution degree (operating environment) 3 (en60947-5-1) impulse withstand voltage (en60947-5-1) between terminals of same polarity 1.5 kv between terminals of different polarity 1.5 kv between other terminals and non-current carrying metallic parts. 2.5 kv insulation resistance 100 m min. (at 500 vdc) vibration resistance malfunction 10 to 55 hz, 0.75 mm single amplitude shock resistance malfunction 100 m/s 2 min. destruction 1,000 m/s 2 min. conditional short-circuit current 100 a (en60947-5-1) conventional free air thermal current (ith) 2.5 a (en60947-5-1) ambient operating temperature -10 to +55c (with no icing) ambient operating humidity 95% max. weight approx. 360 g (connector model) approx. 390 g (terminal block model) specifcations (continued) notes: 1. the above values are initial values. 2. the switch contacts can be used with either standard loads or microloads. once the contacts have been used to switch a load, however, thy cannot be used to switch smaller loads. the contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. *1. the degree of protection is tested using the method specifed by the standard (en60947-5-1). confrm that sealing properties are suffcient for the operating conditions and environment beforehand. although the switch box is protected from dust, oil or water penetration, do not use the D4SL in places where cutting chips, oil, water or chemicals may enter through the key hole on the head, otherwise switch damage or malfunctioning may occur. *2. the durability is for an ambient temperature of 5 to 35c and an ambient humidity of 40% to 70%. for further conditions, consult your sales representative. *3. do not pass a 1 a, 125 vac load through more than 3 circuits. *4. these fgures are minimum requirements for safe operation. *5. these fgures are based on the gs-et-19 evaluation method. *6. this value will vary with the switching frequency, environment, and reliability level. confrm that correct operation is possible with the actual load beforehand. structure structure D4SL- d -d4n connector model D4SL- d -d4 t erminal block model can be mounted from four directions . tw o operation key holes the switch has an indicator on the ba ck of the sw itch as well . can be mounted from four directions . tw o operation key holes the switch has an indicator on the ba ck of the switch as well. the switch has a release ke y on the ba ck of the sw itch as well. the switch has a release ke y on the ba ck of the sw itch as well. can be mounted from four directions . tw o operation key holes the switch has an indicator on the ba ck of the sw itch as well . can be mounted from four directions . tw o operation key holes the switch has an indicator on the ba ck of the switch as well. the switch has a release ke y on the ba ck of the sw itch as well. the switch has a release ke y on the ba ck of the sw itch as well. 4 5 6 10 3 2 1 1 3 5 7 9 2 4 6 8 10 notched side is no . 1 4 5 6 10 3 2 1 1 3 5 7 9 2 4 6 8 10 notched side is no . 1 D4SL safety i nterlock switches www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g67 e1(+) e2(-) 11 21 33 9 10 41 51 63 42 52 64 orange 1 2 3 4 5 6 7 8 12 22 34 e1(+) e2(-) 11 33 9 10 41 51 63 42 52 64 orange 1 2 5 6 3 4 7 8 12 34 structure (continued) structure D4SL- n da and D4SL- ndg D4SL- jdg operating c ycle e xamples for standard models D4SL- da-d4 (m echanical l ock models with special r elease keys) terminal no. and function condition 1 condition 2 condition 3 turning the special release key door open. the door will lock when the door closes. door closed. the door is locked. door closed. the door can be opened. door closed. no power is supplied to the solenoid.the door is unlocked manually. e1-e2 solenoid on 42-11 (nc) 52-21 (nc) door open/closed detection and lock monitor contacts 31-32 (nc) door open/closed detection contact 33-34 (no) door open/closed detection contact 51-52 (nc) 61-62 (nc) lock monitor contact 63-64 (no) lock monitor contact note: numbers inside the boxes are terminal numbers printed on the product. note: numbers inside the boxes are terminal numbers printed on the product. D4SL- dg-d4 (solenoid l ock models with special r elease keys) terminal no. and function even when the door is closed, it does not lock until power is supplied to the solenoid. door closed. the door is locked. door closed. the door can be opened. e1-e2 solenoid on 42-11 (nc) 52-21 (nc) door open/closed detection and lock monitor contacts 31-32 (nc) door open/closed detection contact 33-34 (no) door open/closed detection contact 51-52 (nc) 61-62 (nc) lock monitor contact 63-64 (no) lock monitor contact the shaded areas indicate the contact is closed and power is supplied to the solenoid. door open/closed detection and lock monitor contacts: can be used in safety circuits because of the direct opening mechanisms. door open/closed detection contact: can be used to confrm whether the key is inserted and to monitor the open/ closed status of a door. lock monitor contact: can be used to confrm whether power is supplied to the solenoid and to monitor whether or not a door can be opened or closed. notes: 1. the door open/closed detection and lock monitor contact confguration depends on the model. 2. if a current is detected in the solenoid lock model (built-in switches; n,p,q,r), before the door is closed, the door will remain unlocked. be sure to supply power to the solenoid after the door is closed. retur n to condition 1 D4SL safety i nterlock switches www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g68 connections internal c ircuit diagram c ircuit connection example ? direct opening contacts used as safety-circuit input are indicated with the mark. ? do not switch circuits for three or more standard loads at the same time. doing so may adversely affect insulation performance. ? dc solenoids have polarity. (e1: positive, e2: negative) confrm terminal polarity before wiring. connection e xample for D4SL- jdg terminals 12-41 are connected internally and so connect terminals 11-42 for safety-circuit input. (bia gs-et-19) connection e xample for D4SL- kdg terminals 12-41 are connected internally and so connect terminals 11-42 for safety-circuit input. (bia gs-et-19) connection e xample for D4SL- ldg terminals 12-41 are connected internally and so connect terminals 11-42 for safety-circuit input. (bia gs-et-19) d d 24 vdc r led e1(+) e2(-) z d control circuit e1 (+) e2 (-) to control circuit to control circuit 11 51 33 lo ck monitor sw itch 9 10 led 41 63 42 52 64 1 2 5 6 3 4 7 8 12 34 to control circuit to saf ety circuit door open/ closed detection sw itch e1 (+) e2 (-) to control circuit to control circuit 11 51 33 lo ck monitor sw itch 9 10 led 41 62 42 52 61 1 2 5 6 3 4 7 8 12 34 to control circuit to saf ety circuit door open/ closed detection sw itch e1 (+) e2 (-) to control circuit to control circuit 11 51 31 lo ck monitor sw itch 9 10 led 41 63 42 52 64 1 2 5 6 3 4 7 8 12 32 to control circuit to saf ety circuit door open/ closed detection sw itch connection e xample for D4SL- mdg terminals 12-41 are connected internally and so connect terminals 11-42 for safety-circuit input. (bia gs-et-19) connection e xample for D4SL- n da and D4SL- ndg terminals 12- 41, and 22- 51 are connected internally and so connect terminals 11-42, and 21-52 for safety-circuit input. (bia gs-et-19) connection e xample for D4SL- pda and d4s l- pdg terminals 12-41, and 22-51 are connected internally and so connect terminals 11-42, and 21-52 for safety-circuit input. (bia gs-et-19) connection e xample for D4SL- qda and d4s l- qdg terminals 12-41, and 22-51 are connected internally and so connect terminals 11-42, and 21-52 for safety-circuit input. (bia gs-et-19) connection e xample for D4SL- r da and D4SL- rdg terminals 12-41, and 22-51 are connected internally and so connect terminals 11-42, and 21-52 for safety-circuit input. (bia gs-et-19) e1 (+) e2 (-) to control circuit to control circuit 11 51 31 lo ck monitor sw itch 9 10 led 41 62 42 52 61 1 2 5 6 3 4 7 8 12 32 to control circuit to saf ety circuit door open/ closed detection sw itch e1 (+) e2 (-) to saf ety circuit to control circuit 11 21 33 lo ck monitor sw itch 9 10 led 41 51 63 42 52 64 1 2 3 4 5 6 7 8 12 22 34 to control circuit to saf ety circuit door open/closed detection switch e1 (+) e2 (-) to saf ety circuit to control circuit 11 21 33 lo ck monitor sw itch 9 10 led 41 51 61 42 52 62 1 2 3 4 5 6 7 8 12 22 34 to control circuit to saf ety circuit door open/closed detection switch e1 (+) e2 (-) to saf ety circuit to control circuit 11 21 31 lo ck monitor sw itch 9 10 led 41 51 63 42 52 64 1 2 3 4 5 6 7 8 12 22 32 to control circuit to saf ety circuit door open/closed detection switch e1 (+) e2 (-) to saf ety circuit to control circuit 11 21 31 lo ck monitor sw itch 9 10 led 41 51 61 42 52 62 1 2 3 4 5 6 7 8 12 22 32 to control circuit to saf ety circuit door open/closed detection switch D4SL safety i nterlock switches www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g69 on strok e 42-11 52-51 34-33 64-63 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-51 34-33 62-61 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-51 32-31 64-63 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-51 32-31 62-61 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-21 34-33 64-63 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-21 34-33 62-61 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-21 32-31 64-63 operation ke y inser tion completion positio n extraction completion position loc k position on strok e 42-11 52-21 32-31 62-61 operation ke y inser tion completion positio n extraction completion position loc k position contact form indicates conditions where the key is inserted and the lock is applied. terminals 12 and 41, 51 and 22 are connected internally (as per bia gs-et-19). model contact (door open/ closed detection and lock monitor) c ontact form operating pattern remarks l ock monitor door open/ closed detection D4SL- jd -d 1nc/1no + 2nc/1no D4SL- kd -d 1nc/1no + 3nc D4SL- ld -d 2nc + 2nc/1no D4SL- md -d 2nc + 3nc D4SL- nd -d 2nc/1no + 2nc/1no D4SL- pd -d 2nc/1no + 3nc D4SL- qd -d 3nc + 2nc/1no D4SL- rd -d 3nc + 3nc c onnections (continued) 42 52 51 64 63 41 12 door open/closed detection loc k monitor 11 34 33 42 52 51 62 61 41 12 11 34 33 door open/closed detection loc k monitor 42 52 51 64 63 41 12 11 32 31 door open/closed detection loc k monitor 42 52 51 62 61 41 12 11 31 32 door open/closed detection loc k monitor 42 52 51 64 63 41 12 door open/closed detection loc k monitor 11 34 33 21 22 42 52 51 62 61 41 12 11 34 33 21 22 door open/closed detection loc k monitor 42 52 51 64 63 41 12 11 32 31 21 22 door open/closed detection loc k monitor 42 52 51 62 61 41 12 11 21 22 31 32 door open/closed detection loc k monitor only nc contact 11-12 has a certifed direct opening mechanism. the terminals 42-11, 33-34, 51-52, and 64-63 can be used as unlike poles. only nc contact 11-12 has a certifed direct opening mechanism. the terminals 42-11, 33-34, 51-52, and 62-61 can be used as unlike poles. only nc contact 11-12 and 31-32 have a certifed direct opening mechanism. the terminals 42-11, 33-34, 51-52, and 64-63 can be used as unlike poles. only nc contact 11-12 and 31-32 have a certifed direct opening mechanism. the terminals 42-11, 33-34, 51-52, and 62-61 can be used as unlike poles. only nc contact 11-12 and 21-22 have a certifed direct opening mechanism. the terminals 42-11, 52-21, 34-33, and 64-63 can be used as unlike poles. only nc contact 11-12 and 21-22 have a certifed direct opening mechanism. the terminals 42-11, 52-21, 34-33, and 62-61 can be used as unlike poles. only nc contact 11-12, 21-22, and 31-32 have a certifed direct opening mechanism. the terminals 42-11, 52-21, 32-31, and 64-63 can be used as unlike poles. only nc contact 11-12, 21-22, and 31-32 have a certifed direct opening mechanism. the terminals 42-11, 52-21, 32-31, and 62-61 can be used as unlike poles. D4SL safety i nterlock switches www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g70 1- conduit 2- co ve r mounting scr ew conduit cap led indicators led indicators release ke y led indicators side mounting three , 4.3 dia. mounting hole fr ont-side mounting 2, 4.3 dia. mounting hole pre-tr av el distance operation ke y 41.7 0.2 41.7 0.2 41.7 0.2 41.7 0.2 38.5 38.7 0.2 10 22 0.2 37 39 39 26.3 26.3 spacers release key a a b b 42.9 31.5 4 79.1 126.8 0.8 (8) (17.6) (63.3) (169.7) (55) (55) (63.3) (1) 26 dia. 4.5 dia. (depth: 1.6) 4.5 dia. (depth: 1.6) 4.5 dia. (depth: 1.6) (11.4) (11.4) (17.6) a - a b - b 9 29.2 29.2 head cap 24.7 22 0.2 4.5 dia. (depth : 1.6) led indicators release ke y led indicators fr ont-side mounting 2, 4.3 dia. mounting hole 41.7 0.2 41.7 0.2 41.7 0.2 38.5 38.7 0.2 10 22 0.2 24.7 22 0.2 37 39 39 42.9 31.5 4 79.1 101.9 0.8 (8) (17.6) (63.3) (144.8) (55) (1) 26 dia. 4.5 dia. (depth: 1.6) 4.5 dia. (depth: 1.6) (11.4) 41.7 0.2 26.3 26.3 release key (55) (63.3) 4.5 dia. (depth: 1.6) 4.5 dia. (depth: 1.6) (11.4) (17.6) a - a b - b led indicators spacers a a b b pre-tr av el distance operation ke y 9 29.2 29.2 head cap 1- conduit 2- co ve r mounting scr ew conduit cap side mounting three , 4.3 dia. mounting hole D4SL safety i nterlock switches operating characteristics D4SL- d - d4n key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 15 mm max. m ovement before being locked 3 mm min. operating characteristics D4SL- d - d4 key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 15 mm max. m ovement before being locked 3 mm min. unless otherwise specifed, a tolerance of 0.4 mm applies to all dimensions. D4SL- d -d4 dimensions and operating characteristics (mm) switches D4SL- d -d4n www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g71 D4SL safety i nterlock switches dimensions and operating c haracteristics (continued) (mm) operation keys D4SL-k1 unless otherwise specifed, a tolerance of 0.4 mm applies to all dimensions. D4SL-k1s 22.7 2-9 dia. 2-4.3 dia. mounting ru bber 2 28 28 21.5 35 20 (5.2) 12 22.7 2 28 19.5 13 4-r2.15 7 7 4.3 35 15 22.7 2 28 28 21.5 7 7 4.3 4-r2.15 35 15 22.7 28 17.2 35 2 14.5 8 2-9 dia. 2-4.3 dia. mounting ru bber 20 12 22.7 2 28 15.6 4-r2.15 35 7 7 14.5 4.3 8 15 28 22.7 30 15 4.5 dia. 8 dia. 9 dia. 40 angle adjustment bolt 56 20 17.7 4 D4SL-k1g D4SL-k2 D4SL-k2g D4SL-k3 connector c able D4SL-cn connector no. lead wire color connector no. lead wire color 1 black 6 green/white 2 black/white 7 yellow 3 red 8 yellow/white 4 red/white 9 brown 6 green 10 brown white model l size D4SL-cn1 1 m D4SL-cn3 3 m D4SL-cn5 5 m connector ca ble aw g22, 10 conductors * * all 10 lead wires laid bare . connector pin no . 10 9 8 7 6 5 4 3 2 1 (30) l 40 (150) (5) www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g72 D4SL safety i nterlock switches dimensions and operating c haracteristics (continued) (mm) operating key mounting D4SL-D4SL-k1 (with f ront-inserted operation key) D4SL-D4SL-k1 (with t op-inserted operation key) D4SL-D4SL-k1s (with f ront-inserted operation key) D4SL-D4SL-k1s (with t op-inserted operation key) D4SL-D4SL-k1g (with f ront-inserted operation key) D4SL-D4SL-k1g (with t op-inserted operation key) (37) 31.5 ve rt ical inser tion radius r 200 center tolerance of key hole : 0.8 59 min. 61.5 max. ke y inse rtion position (37) (15) ho ri zontal inser tion radius r 180 center tolerance of ke y hole : 0.8 59 min. 61.5 max. ke y inse rtion position 9 (38.5) center tolerance of ke y hole : 0.8 60.5 min. 63 max. ke y inser tion positio n ve rt ical inser tion radius r 200 (38.5) 60.5 min. 63 max. ke y inser tion positio n (15) ho ri zontal inser tion radius r 180 center tolerance of key hole: 0.8 (37) 31.5 ve rt ical inser tion radius r 200 center tolerance of key hole : 0.8 50.5 min. 53 max. ke y inse rtion position (37) (15) ho ri zontal inser tion radius r 180 center tolerance of ke y hole : 0.8 50.5 min. 53 max. ke y inse rtion position (38.5) 52 min. 54.5 max. ke y inse rtion position 52 min. 54.5 max. ke y inse rtion position (15) hor iz ontal inser tion radius r 180 center tolerance of key hole : 0.8 (38.5) 9 center tolerance of key hole : 0.8 ve rt ical inser tion radius r 200 (37) (28.9) (2.6) 31.5 ve rt ical inser tion radius r 140 59 min. 61.5 max. ke y inse rtion position (37) center tolerance of key hole : 0.8 59 min. 61.5 max. ke y inse rtion position (pitch 12 mm) (pitch 20 mm) ho ri zontal inser tion radius pitch 12 mm r 120 pitch 20 mm r 170 center tolerance of ke y hole : 0.8 (38.5) (38.5) (2.6) (6.4) 9 center tolerance of key hole: 0.8 60.5 min. 63 max. ke y inse rtion position 60.5 min. 63 max. ke y inse rtion position ve rt ical inser tion radius r 140 (pitch 12 mm) (pitch 20 mm) ho ri zontal inser tion radius pitch 12 mm r 120 pitch 20 mm r 170 center tolerance of key hole: 0.8 www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g73 D4SL safety i nterlock switches dimensions and operating c haracteristics (continued) (mm) operating key m ounting (continued) D4SL-D4SL-k2 (with f ront-inserted operation key) D4SL-D4SL-k2 (with t op-inserted operation key) D4SL-D4SL-k3 (with f ront-inserted operation key) D4SL-D4SL-k3 (with t op-inserted operation key) (37) (37) 31.5 (8) (39.5) ve rt ical inser tion radius r 200 ho ri zontal inser tion radius r 180 center tolerance of ke y hole : 0.8 (15) center tolerance of ke y hole: 0.8 53.1 min. 55.6 max. ke y inse rtion position 53.1 min. 55.6 max. ke y inse rtion position (38.5) center tolerance of key hole: 0.8 54.6 min. 57.1 max. ke y inse rtion position 54.6 min. 57.1 max. ke y inse rtion position (38.5) (8) 9 (17) (15) center tolerance of key hole: 0.8 hor iz ontal inser tion radius r 180 ve rt ical inser tion radius r 200 center tolerance of key hole: 0.8 (pitch 12 mm) (pitch 20 mm) hor iz ontal inser tion radius pitch 12 mm r 120 pitch 20 mm r 170 (37) (37) 31.5 (8) (39.5) ve rt ical inser tion radius r 140 center tolerance of key hole: 0.8 54.7 min. 57.2 max. ke y inser tion position 54.7 min. 57.2 max. ke y inser tion position center tolerance of key hole: 0.8 56.2 min. 58.7 max. ke y inse rtion position (38.5) (8) 9 (17) ve rt ical inser tion radius r 140 (38.5) 56.2 min. 58.7 max. ke y inse rtion position center tolerance of key hole: 0.8 (pitch 12 mm) (pitch 20 mm) ho ri zontal inser tion radius pitch 12 mm r 120 pitch 20 mm r 170 center tolerance of key hole: 0.8 ve rt ical inser tion radius r 200 (37) 55.2 min. 57.7 max. (31.5) (40 0.15 ) center tolerance of key hole: 0.8 ke y inser tion position (37) 55.2 min. 57.7 max. ke y inser tion position ho ri zontal inser tion radius r 50 ve rt ical inser tion radiu s r 200 center tolerance of key hole : 0.8 (38.5) (38.5) (9) 40 56.7 min. 59.2 max. ke y inser tion position 56.7 min. 59.2 max. ke y inser tion position center tolerance of ke y hole : 0.8 hor iz ontal inser tion radius r 50 D4SL-D4SL-k2g (with f ront-inserted operation key) D4SL-D4SL-k2g (with t op-inserted operation key) www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g74 D4SL safety i nterlock switches application examples g9sa-321-t (24 va c/vdc) + D4SL- da-d4 (m echanical l ock t ype) c ircuit diagram (m anual reset) 9 1 2 3 4 5 6 7 8 10 th sa s2 open s4 km1 km2 42 41 12 11 plc plc a1 a2 t11 t12 t31 t32 13 23 33 43 53 61 1 2 3 4 5 6 jp k3 3 4 2 5 k4 k1 k2 k1 k1 pe t21 t23 t22 a b 14 24 34 km1 km2 km1 km2 m 44 54 62 k2 k2 6 k3 1 a b offdela y timer control circuit k4 a b (operation inst ru ction) f eedbac k loop stop signal guard loc k release signal km1 km2 s3 motor controller s1 k1 and k2 (nc) k1 and k2 (no) k3 and k4 (nc) k3 and k4 (no) km1 and km2 (nc) km1 and km2 (no) operation instr uction motor rotation off-dela y time guard can be opened reset s witch s3 stop signal loc k release signal s4 limit s witch s1 guard lo ck saf ety-door switch s2 guard opens notes: 1. the above example circuit is for category 3. 2. numbers inside the boxes are terminal numbers printed on the product. s1: safety limit switch with direct opening mechanism (d4b-n, d4n, d4f) s2: guard lock safety-door switch s3: reset switch s4: lock release switch km1 and km2: magnetic contactor m: 3-phase motor www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g75 D4SL safety i nterlock switches application e xamples (continued) g 9sa-301 (24 va c/vdc) + D4SL- dg-d4 (solenoid l ock t ype) c ircuit diagram (auto-reset) th sa plc plc 1 2 3 4 5 6 7 8 10 9 a1 a2 t11 t12 k1 k1 pe t21 t23 t22 k2 k2 6 a b 1 2 3 4 5 6 jp 13 t32 t31 23 33 41 2 5 3 1 k1 k2 4 a b control circuit 14 24 34 42 a b f eedbac k loop km1 km2 km1 km2 m (operation instr uction) motor controller loc k signal operation signal km1 km2 41 42 12 11 s2 s1 open 12 11 limit s witch s1 guard lo ck sa fety-door switch s2 k1 and k2 (no) k1 and k2 (nc) km1 and km2 (nc) km1 and km2 (no) guard opens operation signal loc k signal www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g76 D4SL safety i nterlock switches switch D4SL C C 1 2 3 4 5 6 7 1 conduit size 2: g1/2 (conduit) 3: 1/2-14 npt (1 conduit) *1 4: m20 (1 conduit) 2 built-in switch *2 5-contact model j: 1nc/1no + 2nc/1no k: 1nc/1no + 3nc l: 2nc + 2nc/1no m: 2nc + 3nc 6-contact model n: 2nc/1no + 2nc/1no p: 2nc/1no + 3nc q: 3nc + 2nc/1no r: 3nc + 3nc 3 head material d: metal 4 door lock and release a: mechanical lock/24 vdc solenoid release g: 24 vdc solenoid lock/mechanical release 5 indicator d: 24 vdc (orange led indicator) 6 release key type blank: standard 4: special release key (note: release keys are provided) 7 connection method blank: terminal block n: connector *3 *1. m20, includes m20-to-1/2-14npt conversion adapter (to be released) *2. if a current is detected in the solenoid lock model (built-in switches; n, p, q, r), before the door is closed, the door will remain unlocked. be sure to close the door before turning on the solenoid. *3 connector cables are not included with the connector type and are to be purchased separately. ordering operation key D4SL-k 1 2 1 operation key type 1: horizontal mounting 2: vertical mounting 3: adjustable mounting (horizontal) 1 key type blank: no cushion rubber g: cushion rubber s: no cushion rubber, short type model number structure www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g77 D4SL safety i nterlock switches ordering (continued) list of models m echanical lock/24 vdc solenoid release (g 1/2, m20 conduit types) (operation keys are sold separately) r elease key type wiring method solenoid voltage/ indicator l ock and release type contact confguration (door open/closed detection switch and lock monitor switch contacts) c onduit size model standard connector 24 vdc orange mechanical lock/ solenoid release 2nc/1no + 2nc/1no g1/2 D4SL-2nda-dn m20 D4SL-4nda-dn 2nc/1no + 3nc g1/2 D4SL-2pda-dn m20 D4SL-4pda-dn 3nc + 2nc/1no g1/2 D4SL-2qda-dn m20 D4SL-4qda-dn 3nc + 3nc g1/2 D4SL-2rda-dn m20 D4SL-4rda-dn terminal block 2nc/1no + 2nc/1no g1/2 D4SL-2nda-d m20 D4SL-4nda-d 2nc/1no + 3nc g1/2 D4SL-2pda-d m20 D4SL-4pda-d 3nc + 2nc/1no g1/2 D4SL-2qda-d m20 D4SL-4qda-d 3nc + 3nc g1/2 D4SL-2rda-d m20 D4SL-4rda-d special release key connector 2nc/1no + 2nc/1no g1/2 D4SL-2nda-d4n * m20 D4SL-4nda-d4n * 2nc/1no + 3nc g1/2 D4SL-2pda-d4n * m20 D4SL-4pda-d4n * 3nc + 2nc/1no g1/2 D4SL-2qda-d4n * m20 D4SL-4qda-d4n * 3nc + 3nc g1/2 D4SL-2rda-d4n * m20 D4SL-4rda-d4n * terminal block 2nc/1no + 2nc/1no g1/2 D4SL-2nda-d4 * m20 D4SL-4nda-d4 * 2nc/1no + 3nc g1/2 D4SL-2pda-d4 * m20 D4SL-4pda-d4 * 3nc + 2nc/1no g1/2 D4SL-2qda-d4 * m20 D4SL-4qda-d4 * 3nc + 3nc g1/2 D4SL-2rda-d4 * m20 D4SL-4rda-d4 * note: the recommended models for equipment and machinery being exported to europe are those with an m20 conduit sizes, and for north america, the recommended models are those with a 1/2-14npt conduit sizes. * these models received korean s-mark certifcation www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g78 D4SL safety i nterlock switches list of m odels (continued) 24 vd c solenoid lock/m echanical release (g 1/2, m20 conduit types) (operation keys are sold separately) ordering (continued) r elease key type wiring method solenoid voltage/ indicator l ock and release type contact confguration (door open/closed detection switch and lock monitor switch contacts) c onduit size model standard connector 24 vdc orange solenoid lock/ mechanical release 1nc/1no + 2nc/1no g1/2 D4SL-2jdg-dn m20 D4SL-4jdg-dn 1nc/1no + 3nc g1/2 D4SL-2kdg-dn m20 D4SL-4kdg-dn 2nc + 2nc/1no g1/2 D4SL-2ldg-dn m20 D4SL-4ldg-dn 2nc + 3nc g1/2 D4SL-2mdg-dn m20 D4SL-4mdg-dn 2nc/1no + 2nc/1no g1/2 D4SL-2ndg-dn m20 D4SL-4ndg-dn 2nc/1no + 3nc g1/2 D4SL-2pdg-dn m20 D4SL-4pdg-dn 3nc + 2nc/1no g1/2 D4SL-2qdg-dn m20 D4SL-4qdg-dn 3nc + 3nc g1/2 D4SL-2rdg-dn m20 D4SL-4rdg-dn terminal block 1nc/1no + 2nc/1no g1/2 D4SL-2jdg-d m20 D4SL-4jdg-d 1nc/1no + 3nc g1/2 D4SL-2kdg-d m20 D4SL-4kdg-d 2nc + 2nc/1no g1/2 D4SL-2ldg-d m20 D4SL-4ldg-d 2nc + 3nc g1/2 D4SL-2mdg-d m20 D4SL-4mdg-d 2nc/1no + 2nc/1no g1/2 D4SL-2ndg-d m20 D4SL-4ndg-d 2nc/1no + 3nc g1/2 D4SL-2pdg-d m20 D4SL-4pdg-d 3nc + 2nc/1no g1/2 D4SL-2qdg-d m20 D4SL-4qdg-d 3nc + 3nc g1/2 D4SL-2rdg-d m20 D4SL-4rdg-d note: the recommended models for equipment and machinery being exported to europe are those with an m20 conduit sizes, and for north america, the recommended models are those with a 1/2-14npt conduit sizes. * these models received korean s-mark certifcation www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g79 D4SL safety i nterlock switches list of m odels (continued) 24 vd c solenoid lock/m echanical release (g 1/2, m20 conduit types) (operation keys are sold separately) ordering (continued) r elease key type wiring method solenoid voltage/ indicator l ock and release type contact confguration (door open/closed detection switch and lock monitor switch contacts) c onduit size model special release key connector 24 vdc orange solenoid lock/ mechanical release 1nc/1no + 2nc/1no g1/2 D4SL-2jdg-d4n m20 D4SL-4jdg-d4n 1nc/1no + 3nc g1/2 D4SL-2kdg-d4n m20 D4SL-4kdg-d4n 2nc + 2nc/1no g1/2 D4SL-2ldg-d4n m20 D4SL-4ldg-d4n 2nc + 3nc g1/2 D4SL-2mdg-d4n m20 D4SL-4mdg-d4n 2nc/1no + 2nc/1no g1/2 D4SL-2ndg-d4n * m20 D4SL-4ndg-d4n * 2nc/1no + 3nc g1/2 D4SL-2pdg-d4n * m20 D4SL-4pdg-d4n * 3nc + 2nc/1no g1/2 D4SL-2qdg-d4n * m20 D4SL-4qdg-d4n * 3nc + 3nc g1/2 D4SL-2rdg-d4n * m20 D4SL-4rdg-d4n * terminal block 1nc/1no + 2nc/1no g1/2 D4SL-2jdg-d4 m20 D4SL-4jdg-d4 1nc/1no + 3nc g1/2 D4SL-2kdg-d4 m20 D4SL-4kdg-d4 2nc + 2nc/1no g1/2 D4SL-2ldg-d4 m20 D4SL-4ldg-d4 2nc + 3nc g1/2 D4SL-2mdg-d4 m20 D4SL-4mdg-d4 2nc/1no + 2nc/1no g1/2 D4SL-2ndg-d4 * m20 D4SL-4ndg-d4 * 2nc/1no + 3nc g1/2 D4SL-2pdg-d4 * m20 D4SL-4pdg-d4 * 3nc + 2nc/1no g1/2 D4SL-2qdg-d4 * m20 D4SL-4qdg-d4 * 3nc + 3nc g1/2 D4SL-2rdg-d4 * m20 D4SL-4rdg-d4 * note: the recommended models for equipment and machinery being exported to europe are those with an m20 conduit sizes, and for north america, the recommended models are those with a 1/2-14npt conduit sizes. * these models received korean s-mark certifcation www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g80 D4SL safety i nterlock switches list of m odels (continued) m echanical lock/24 vdc solenoid release (1/2-14npt conduit type) (operation keys are sold separately) ordering (continued) r elease key type wiring method solenoid voltage/ indicator l ock and release type contact confguration (door open/closed detection switch and lock monitor switch contacts) c onduit size model standard connector 24 vdc orange mechanical lock/ solenoid release 2nc/1no + 2nc/1no 1/2-14npt D4SL-3nda-dn 2nc/1no + 3nc D4SL-3pda-dn 3nc + 2nc/1no D4SL-3qda-dn 3nc + 3nc D4SL-3rda-dn terminal block 2nc/1no + 2nc/1no D4SL-3nda-d 2nc/1no + 3nc D4SL-3pda-d 3nc + 2nc/1no D4SL-3qda-d 3nc + 3nc D4SL-3rda-d special release key connector 2nc/1no + 2nc/1no D4SL-3nda-d4n * 2nc/1no + 3nc D4SL-3pda-d4n * 3nc + 2nc/1no D4SL-3qda-d4n * 3nc + 3nc D4SL-3rda-d4n * terminal block 2nc/1no + 2nc/1no D4SL-3nda-d4 * 2nc/1no + 3nc D4SL-3pda-d4 * 3nc + 2nc/1no D4SL-3qda-d4 * 3nc + 3nc D4SL-3rda-d4 * 24 vd c solenoid lock/m echanical release (1/2-14npt conduit type) (operation keys are sold separately) r elease key type wiring method solenoid voltage/ indicator l ock and release type contact confguration (door open/closed detection switch and lock monitor switch contacts) c onduit size model standard connector 24 vdc orange solenoid lock/ mechanical release 1nc/1no + 2nc/1no 1/2-14npt D4SL-3jdg-dn 1nc/1no + 3nc D4SL-3kdg-dn 2nc + 2nc/1no D4SL-3ldg-dn 2nc + 3nc D4SL-3mdg-dn 2nc/1no + 2nc/1no D4SL-3ndg-dn 2nc/1no + 3nc D4SL-3pdg-dn 3nc + 2nc/1no D4SL-3qdg-dn 3nc + 3nc D4SL-3rdg-dn terminal block 1nc/1no + 2nc/1no D4SL-3jdg-d 1nc/1no + 3nc D4SL-3kdg-d 2nc + 2nc/1no D4SL-3ldg-d 2nc + 3nc D4SL-3mdg-d 2nc/1no + 2nc/1no D4SL-3ndg-d 2nc/1no + 3nc D4SL-3pdg-d 3nc + 2nc/1no D4SL-3qdg-d 3nc + 3nc D4SL-3rdg-d special release key connector 24 vdc orange 1nc/1no + 2nc/1no D4SL-3jdg-d4n 1nc/1no + 3nc D4SL-3kdg-d4n 2nc + 2nc/1no D4SL-3ldg-d4n 2nc + 3nc D4SL-3mdg-d4n 2nc/1no + 2nc/1no D4SL-3ndg-d4n * 2nc/1no + 3nc D4SL-3pdg-d4n * 3nc + 2nc/1no D4SL-3qdg-d4n * 3nc + 3nc D4SL-3rdg-d4n * terminal block 1nc/1no + 2nc/1no D4SL-3jdg-d4 1nc/1no + 3nc D4SL-3kdg-d4 2nc + 2nc/1no D4SL-3ldg-d4 2nc + 3nc D4SL-3mdg-d4 2nc/1no + 2nc/1no D4SL-3ndg-d4 * 2nc/1no + 3nc D4SL-3pdg-d4 * 3nc + 2nc/1no D4SL-3qdg-d4 * 3nc + 3nc D4SL-3rdg-d4 * note: the recommended models for equipment and machinery being exported to north america are those with a 1/2-14npt conduit sizes. * these models received korean s-mark certifcation = highlighted r apid delivery products are available for shipment today or within five days. www.datasheet.co.kr datasheet pdf - http://www..net/
for the latest information on the internet: www.sti.com omr on scientific technologies , inc. usa tel. 1/888/510-4357 canada tel. 1/866/986-6766 g g81 D4SL safety i nterlock switches ordering (continued) operation keys t ype model horizontal mounting D4SL-k1 horizontal mounting (short) D4SL-k1s horizontal mounting (cushion rubber) D4SL-k1g vertical mounting D4SL-k2 vertical mounting (cushion rubber) D4SL-k2g adjustable (horizontal) D4SL-k3 t ype model D4SL-sk10-lk slide key connector c ables t ype model 1 m D4SL-cn1 3 m D4SL-cn3 5 m D4SL-cn5 = highlighted r apid delivery products are available for shipment today or within five days. special release ke y the head can be mounted in 4 directions . tw o conduits (hor iz ontal and ver tical) bac k-mounting is also possib le . special r elease key t ype model special release key for d4gl, d4jl, d4nl, and D4SL switches d4nl-rk www.datasheet.co.kr datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of D4SL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X